Examination & Optimisation Flow Conditions Heat Exchanger

Task:
CFD modelling and investigation reducing damages and scaling upstream of heat exchanger

Scope of work:

  • CFD modelling and trouble-shooting regarding damages in the unit
  • Development of an improved flow design
  • CAD engineering for implementation of the revamping
  • Supervising during revamping

Results:

  • No damages at heat tubes anymore
  • Minimisation of scaling
  • Increased plant availability
  • Energy savings due to reduced pressure loss